ASTM D1143 PDF

ASTM D Test Method for Piles Under Static Axial Compressive Load This standard has been. prepared to cover routine methods of testing to determine if a . Grout Systems performs compression load testing based on ASTM D, the standard test method for deep foundations under static axial compressive load. ASTM D Standard Test Method for Piles under Static Axial Compressive Load.

Author: Jugul Tugami
Country: Austria
Language: English (Spanish)
Genre: Medical
Published (Last): 22 September 2018
Pages: 409
PDF File Size: 12.97 Mb
ePub File Size: 14.16 Mb
ISBN: 593-6-81840-220-4
Downloads: 4923
Price: Free* [*Free Regsitration Required]
Uploader: Zugal

Ast to Active This link will always route to the current Active version of the standard. Loading x1143 Excess of Maintained Test Optional. How one applies the results obtained using this standard is beyond its scope. Constant Movement Increment Test Optional. The engineer in responsible charge of the foundation design, referred d11143 herein as the Engineer, shall approve any deviations, deletions, or additions to the requirements of this standard.

Historical Version s – view previous versions of standard. In this system, the pound [lbf] represents a unit of force [weight], while the unit for mass is slugs. Combining values from the two systems may result in non-conformance with the standard. Interested in compression pile load testing, contact the experienced team at Grout Systems. The adtm of the result produced by this test method is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used.

These methods apply to all deep foundations, referred to herein as pilesthat function in a manner similar to driven piles or cast-in-place piles, regardless of their method of installation, and may be used for testing single piles or pile groups.

  LA TZOUMAZ PISTE MAP PDF

See Appendix X1 for comments regarding some of the factors influencing the interpretation of test results. Grout Systems performs compression load testing s1143 on ASTM D, the standard test method for deep foundations under static axial compressive load. Procedure A Quick Test 8. Compression load tests apply to all deep foundations that function in a d113 similar to driven piles or cast-in-place piles, regardless of their method of installation, and may be used for testing single piles or pile groups.

Test results may also provide information used to assess the distribution of side shear resistance d1134 the pile shaft, the amount of end bearing developed at the pile toe, and the long-term load-deflection behavior. The test measures the axial deflection of a vertical or inclined deep foundation when loaded in static axial compression.

Test results can be evaluated to determine if the pile or pile group has an ultimate static capacity and a deflection at service load satisfactory to support a specific foundation. Cyclic Loading Test Optional. Constant Time Interval Test Optional. The test results may not represent the long-term performance of a deep foundation.

Reliable results depend on many factors; Practice D provides a means of evaluating some of those factors. Tests that achieve a failure load may help the designer improve the efficiency of the foundation by reducing the piling length, quantity, or size.

Compression (ASTM D1143)

When performed as part of a multiple-pile test program, the designer may also use the results to assess the viability of different piling types and the variability of the test site.

Constant Rate of Penetration Test Optional.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but r1143 not provided as part of the standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. This standard also includes illustrations and appendices intended only for explanatory or advisory use. These notes and footnotes excluding those in tables and figures shall not be considered as requirements of the standard.

  COMPLEAT VAMPYRE NIGEL JACKSON PDF

A foundation designer may evaluate the test results to determine if, after applying an appropriate factor of safety, the pile or pile group has an ultimate static capacity and a deflection at service load satisfactory to support a specific foundation.

Compression (ASTM D) | Grout Systems

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Test results may also provide information used to assess the distribution of side shear resistance along the pile shaft, the amount of end bearing developed at the pile toe, and the long-term load-deflection behavior.

The text of this standard references notes and footnotes d143 provide explanatory material. Users of this test method are cautioned that compliance with Practice D does not in itself assure reliable results.

Imperative sentences indicate mandatory provisions. When performed as part of a multiple-pile test program, the results may also be used to assess the viability of different piling types and the variability of the test site.

Grout Systems Incorporated Grout Systems. Compression Load Tests provide aetm most reliable relationship between the axial load applied to a deep foundation and the resulting axial movement.